Temperature Gradient; Ventilation; Elevation Limitations; Lighting - Canon imagePRESS 1125 Professional Customer Expectation Document

Table of Contents

Advertisement

5.2 Temperature Gradient

Using an air conditioner during the winter, or if a sudden temperature change
occurs, may have an adverse affect on image positioning. Sudden temperature
changes may cause the paper to bend or contract, cause the machine to
malfunction, and form condensation. To avoid these issues, control the
temperature gradient so that it does not exceed 18°F/H (10°C/H).

5.3 Ventilation

Ensure that there is an air exchange rate of at least 1.5 times per hour, and at least
3
3,885 ft
(110 m
This machine generates a slight amount of ozone during normal use. Although
sensitivity to ozone may vary, this amount is not harmful. Ozone may be more
noticeable during extended use or long production runs, especially in poorly
ventilated rooms. It is recommended that the room be appropriately ventilated,
sufficient to maintain a comfortable working environment, in areas of machine
operation.

5.4 Elevation Limitations

Install this machine at an elevation below 13,123' (4,000 m) and at an air pressure
between 810.6 to 1,013 hPa (0.8 to 1.0 atm).

5.5 Lighting

We recommend installing the machine in a location with at least 500 lux
(29 1/2" (75 cm) above the floor) for normal operation and maintenance.

5.6 Sunlight

Avoid installing the machine in direct sunlight. Direct sunlight has adverse affects
on toner consistency and image quality. If direct sunlight is unavoidable, use
curtains to shade the machine. Be sure that the curtains do not block the
machine's ventilation slots or louvers, or interfere with the electrical cord or power
supply.

5.7 Ammonia

Avoid installing the machine where ammonia is emitted. In a sufficient amount,
ammonia will attack the surfaces of the machine's paper feed and image quality
components, thereby shortening their useful life and increasing the need for
periodic and remedial maintenance.
A professional assessment of the air quality in the room in which the machine is to
be installed is recommended prior to its installation.
Version 3
3
) of space in the location where the machine will be installed.
imagePRESS 1125P Customer Expectations Document
Page 20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagepress 1125p

Table of Contents