Graf AquaControl+ User Information page 16

Fill level measuring device and drinking water supply
Hide thumbs Also See for AquaControl+:
Table of Contents

Advertisement

SWITCHING POINTS
key „OK"
PUMP ON
0-100%
8%
PUMP
OFF
0-100%
6%
VALVE ON
0-100%
10%
VALVE OFF
0-100%
12%
DW INTERVAL
0-14 DAYS
14
DW DURATION
0-60 SEC
30
CLEANER INTERVAL
0-14 DAYS
14
CLEANER DURATION
0-60 SEC
5
CLEANER RINSE AT
INCREMENT
2%
Picture 10: Sub-menu "Switching points"
Press the „OK" button to alter the respective switching points. The value to be altered will
begin to blink. The value may then be adjusted by using the „ " and the „ " buttons.
Press the "OK" button again when the displayed value should be accepted.
Main menu level
Pump ON (The numerical value is always
smaller than with Valve ON.)
Pump OFF (The numerical value is always
smaller than with Pump ON.)
Supply with mains drinking water - ON (The
numerical value is always smaller than with
Valve OFF.)
Supply with mains drinking water -
OFF
Flush the drinking water supply piping every
14 days. The value „0" switches the flushing
off.
Flush the drinking water supply pipes for 30
seconds.
Cleaning the rainwater filter every 14 days
The value 0 switches the cleaning process off.
Cleaning the rainwater filter for 5 seconds
Cleaning the rainwater filter when the fill level
has increased by 2% after rainfall. If the fill
level continues to increase, the rinsing will be
repeated every 3 hours. The value 0 switches
the cleaning process off.