Commercial reference: 2001-030
Developed by CAVIUS
PLEASE
READ THE USER GUIDE
CAREFULLY BEFORE USE AND
RETAIN FOR FUTURE USE!
CAVIUS smoke alarm is designed for private homes,
camping trailers and caravan installations.
+
Technical information:
Diameter: 40mm. Height: 42mm (without mounting base).
Type of alarm: CAVIUS smoke alarm is a photo electric
smoke alarm.
Alarm signal: Fire alarm condition is indicated by a series
of repeated tones. The minimum sound level is 85 dB
at 3 meters.
Battery: Powered by a replaceable 3v CR2 Lithium bat-
tery (included).
Low battery indicator: A short "beep" will sound and
LED flash every 48 seconds when the battery is near the
end of life. In this stage it will continue for a minimum
30 days.
It is recommended to change the smoke alarm after 10
years, or if the alarm has suffered any damage. Alarm
can not be inserted in the base if the battery is not
installed.
Battery replacement:
To replace the battery, detach the smoke alarm from the
mounting base by twisting counterclockwise. Replace
the battery respecting the polarities.
Caution: There is a risk of explosion if the batteries are
replaced by an incorrect type.
Attach the alarm in the mounting base by twisting clock-
wise until it clicks, and test the alarm.
Placement: The smoke alarm is designed for placement on
a ceiling. The smoke alarm should be a minimum of 50
cm from the wall, with a minimum of one smoke alarm
per floor and a maximum distance between smoke alarms
of 10 meters.
Alarm signal: The alarm has a visual and acoustic alert
tone. In the passive state, the LED will flash every 48
seconds to indicate normal function. In an alarm state the
LED will flash and the alarm will emit a sweeping
sound pattern design to alert occupants.
Hush function: In case of unintentional alarm condition
or false alarms, press the side button. This will hush the
alarm for 10 minutes, after which time it will automatically
resume its normal alarm function.
UK
Maintenance: The smoke alarm should be vacuum
cleaned once per quarter, and it can be wiped with a
damp cloth. (Do not open the alarm).
Test the alarm at least once per quarter by pushing the
test button. The alarm will self test and give a loud alarm
tone.
The best places to mount the alarm:
• Place an alarm between possible fire sources and
bedrooms as minimum.
• Alarms on each floor and in hallways and stairways.
• Alarms in each room such as bed rooms and living
rooms.
• Place the alarm where it is reachable in order to test
the battery and for maintenance.
Additional alarms increase the security.
Minimum
Installation of alarm:
1. Detach the alarm from the mounting base by twisting
counter clockwise. Use the mounting base ring to mark
the screw holes on the ceiling. Use the enclosed screws
and plugs to install the mounting base. Once the mounting
base is installed on ceiling, attach the alarm by twisting
clockwise.
Mark up screw holes with a pen
Sound
Chamber filter
Test button
Mounting base
Ceiling
Wall
Minimum 50cm
from wall
Use the enclosed screws
and plugs for installation
2. Pull out the battery isolation strip as shown.
3. After mounting, test the alarm by pushing the test
button on the side and get a loud alarm tone.
Please note: The label in the product must not be
removed as it contains important information regarding
the product.
The alarm may NOT be placed:
• In dusty rooms.
• At the top of high pointed ceilings or in ceiling corners
or within 50 cm of a wall.
• In rooms where the temperature goes out side +4
38
C or above 90% relative humidity.
o
• In kitchen, garage and fireplaces where damp, gases
and smoke could occur.
Fault finding: If the smoke alarm activates without
visible cause, the possible cause could be:
• Dust particles in the smoke chamber which can be
removed by vacuuming the mesh.
• High humidity which can be resolved by drying the
smoke alarm.
If the smoke alarm does not work when the test button
is pushed, the probable cause is a faulty battery. Check if
the battery is worn out and replace it. Always test the
alarm after replacement of battery.
Other information: Do not paint the alarm.
Disposal: For battery and product, please dispose
properly at the end of life. This is electronic waste which
should be recycled.
Please note local regulations about information to your
insurance company regarding installed smoke alarms.
17
0333
EN 14604:2005 + AC :2008
DoP no.: 2001-030
Download DoP document: www.cavius.com
Declared performances 4.1-4.19+5.2-5.24: Passed
The CE mark affixed to this product confirms its compliance
with the European Directives which apply to the product and,
in particular, its compliance with the harmonized specifica-
tions of standard EN 14604 relating to Construction Products
Regulation 305/2011.
CAVIUS
All Rights reserved:
Aps assumes no responsi bility
for any errors, which may appear in this manual. Further-
CAVIUS
more,
Aps reserves the right to alter the hardware,
software, and/or specifications detailed herein at any time
CAVIUS
without notice, and
Aps does not make any
commitment to update the infor mation contained herein. All
the trademarks listed herein are owned by their respective
CAVIUS
owners. Copy right ©
Aps.
Developed by CAVIUS Aps
Julsøvej 16, DK-8600
Manufactured in P.R.C.
to
o
127773 rev2

Advertisement

loading