Good Faith Guidelines for TV Installa�ons Above Appliance
TV on the wall
TV Wall
Bracket
Appliance
Notes:
1. These are good faith recommended clearances only and not a guarantee of compliance with all TV
manufacturers' maximum allowable opera�ng temperatures.
2. Since every home has unique air flow characteris�cs and maximum allowable opera�ng temperatures
can vary from manufacturer to manufacturer and from model to model, actual TV temperatures should
be validated at the �me of each installa�on. TVs should not be used in situa�ons where the actual TV
temperature exceeds the manufacturers' maximum allowable opera�ng temperatures iden�fied in the
TV's technical specifica�ons. Contact the TV's manufacturer directly if you cannot locate this
informa�on or have ques�ons regarding the informa�on.
3. Mantel height and depth must conform to mantle requirements specified in the appliance installa�on
manual.
4.
"C" dimension taken from the top of the hood or appliance opening
5.
Sugges�ons on how to further reduce TV temperatures:
a.
b.
Figure 3.4. Good Faith TV Guidelines
10
TV
Item Minimum Dimensions
A
2.5 in. (64 mm)
B
2 in. (51 mm) min. to 3 in. (76 mm)
C
18 in. (457 mm):
D
Wall Brkt + TV Thickness + 2.5 in. (64 mm)
A
B
Mantel
D
C
Increase "A" dimension.
Increase "C" dimension, however, increasing "B" dimension beyond maximum recommended
typically results in higher temperatures.
Heat & Glo • SLR-X-AU-L Owner's Manual • 2653-981 Rev. B • 5/20
TV recessed into the wall
B
A
C
Appliance