Product Specific Information; Appliance Certification; Gas Pressure Requirements; Glass Specifications - Heat & Glo SLR-X-AU-L Owner's Manual

Table of Contents

Advertisement

2 2

Product Specific Information

A. Appliance Certification
MODEL: SLR-X-AU-L
LABORATORY: IAPMO OCEANA
TYPE: Direct Vent Heater
STANDARD: AS/NZS 5263.1.3
The Heat & Glo gas appliances discussed in this Installer's
Guide have been tested to certification standards and listed
by the applicable laboratories.
This appliance must be installed in accordance with the AS/
NZS 5601.1 rules in force.
B. Gas Pressure Requirements
Inlet Gas Pressure
* Outlet (Manifold) Gas Pressure
Gas Rate
Maximum Gas Consumption
Burner Injector
Pilot Injector
Gas types only through field conversions.
* The allowable Outlet (Manifold) Gas Pressure ranges are: Natural Gas .80 - .95 kPa (.87 kPa nominal) and Propane,
ULPG 2.37 - 2.61 kPa (2.40 kPa nominal). Certification testing setpoint values are shown.
Natural Gas
1.13 - 3.40 kPa
.87 kPa
.405
/
m3
h
31.65 MJ/h
#37 DMS (2.64 mm)
Ø .023 (.584 mm)
Heat & Glo • SLR-X-AU-L Owner's Manual • 2653-981 Rev. B • 5/20
C. Glass Specifications
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
THE GUARD IS FITTED TO THIS APPLIANCE
TO REDUCE THE RISK OF FIRE OR INJURY
FROM BURNS AND NO PART OF IT SHOULD
PERMANENTLY BE REMOVED. FOR PROTEC-
TION OF YOUNG CHILDREN OR THE INFIRM.
A SECONDARY GUARD IS REQUIRED.
Propane
2.75 - 3.40 kPa
2.49 kPa
.134
/
m3
h
27.43 MJ/h
#53 DMS (1.51 mm)
Ø .014 (.356 mm)
ULPG
2.75 - 3.40 kPa
2.49 kPa
.111
/
m3
h
25.30 MJ/h
.057 DMS (1.45 mm)
Ø .010 (.254 mm)
7