Introduction

Solder Fume removal when hand soldering is an often-overlooked work place hazard. Medical
research has confirmed that there is an increase incidence of occupational asthma, chronic
bronchitis, allergic reactions and other health related effects associated with exposure to
solder/flux fumes in the electronics industry.
The Arm-Evac
50 is a self-contained, compact and portable Benchtop filtering fume removal
system.
The Arm-Evac 50 has Airflow Control and Filter Condition Monitoring to alert the
operator when it is time to change the filter and incorporates a high performance 24vDC brush
less/ maintenance free motor for years of trouble free use. The Arm-Evac 50 has been designed
to take up a minimum of bench space and incorporates a utility platform to stack soldering irons
and hand tools etc.
As standard the Arm-Evac 50 operates as a Self Contained Plenum. The plenum type extraction
provides fume removal for a wide capture area.
localized extraction, the Arm-Evac 50 can be configured to offer Arm-Extraction via an optional
accessory. The fumes are drawn from the point of origin through the Static-Safe system, filtered
and returned to the work environment as clean air.
In addition to offering two types of fume collection from a single unit, the Arm-Evac 50 also offers
four levels of Fume Filtration, 1) A General Purpose Filter for normal Soldering applications, 2) A
Clean room Filter for use in clean room environments and 3) An Adhesive Filter for removing
fumes produced from light gluing applications and 4) An Economy Foam filter for larger
applications such as sanding, Benchtop machining & grinding.
Specifications
Arm-Evac 50 System Part Number
System voltage
Flow Rate
Noise Level
Weight
Size H x W x D
Housing
Filter Monitoring
Should the fume capture require a more
8889-0050
120/230 VAC, 50/60Hz
90cfm with std filter @ max
motor speed
45cfm with one Arm open
30cfm with both Arms open
54.5dbA at 2 metres
6kg (13lbs)
250 x 330 x 315mm
(8.5" x 13" x 12.5")
Steel chassis with ABS shell
(static safe)
LED display
4