Pace Arm-Evac 250 Manual

Central filter unit
Hide thumbs Also See for Arm-Evac 250:

Advertisement

Pace Arm-Evac 250 Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Arm-Evac 250 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pace Arm-Evac 250

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 ARM-EVAC ® Central Filter Unit MANUAL NO. 8881-0250 REV. A Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3: Table Of Contents

    Filter Cartridge Notes …………………………………………………… Set-Up……………………………………………………………………. Set-Up (continued)……………………………………………………….. Self Calibration Feature …………………………………………………. Maintenance & Filter Replacement……………………………………... Maintenance (continued)……………………………………………….. Replacement Filter part number………………………………………… PACE Worldwide Warranty ……………………………………………..Equipment Warranty Registration ……………………………………….. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 4: Introduction

    Use of this Manual This manual will provide the user with the basic knowledge to properly operate and maintain the PACE Arm-Evac 250 Fume Extraction System. If you encounter any difficulty operating your system or have any questions, call your local authorized PACE dealer or contact PACE Applications Engineering directly at the United Kingdom Office at: Tel.
  • Page 5: Specification

    Specifications Arm-Evac 250 System Part Numbers 8889-0250 220/240V 50 Hz 8889-0255 110V, 60 Hz Flow Rate with standard filter* Single inlet: 288m³/h (170cfm) Dual Inlet: 170m³/h (100cfm) per inlet Flow Rate with Optional Cleanroom Filter* Single inlet: 255m³/h (150cfm) Dual inlet: 135m³/h (80cfm) per...
  • Page 6: Safety

    Safety PACE Fume Extraction systems are designed to reduce the level of harmful contaminants from the work environment and to assist in the achievement of recommended health and safety requirements for local exhaust ventilation and contaminant removal. Be sure to follow all safety guidelines contained herein and precautions contained in other relevant product safety literature (i.e., Material Safety Data Sheets)
  • Page 7: Filter Cartridge Notes

    Notes To ensure the highest level of performance, use only PACE replacement filters in your PACE Fume Extraction System. BE SURE the new filter cartridge is installed with the airflow arrow pointing downward. Filter Cartridge Notes PACE Fume Extraction Systems are equipped with filters designed to capture particles and noxious gases and odors that are present in the air being filtered.
  • Page 8: Set-Up

    Set up The Arm-Evac 250 has been designed for ease of use and maximum installation flexibility in mind. The following are recommended guidelines for setting up your system. If you have any specific questions that this section does not cover, please consult your PACE Representative or call PACE directly.
  • Page 9: Set-Up (Continued)

    If an inlet port is not connected to a collection device, it must be covered with the inlet cap provided. 6. Accessories The Arm-Evac 250 is designed to be used with one to four collection accessories (i.e. flex arm, any two plenum etc). When using two collection devices, may be used together.
  • Page 10: Self Calibration Feature

    NOTE This procedure must be performed on the Arm-Evac 250 before initial operation, whenever a filter change out occurs and whenever a change in system configuration occurs. DO NOT make any adjustments to the accessory configurations during calibration as this will disrupt the self-calibration process.
  • Page 11: Maintenance & Filter Replacement

    Overheating may occur and cause motor damage if the system is operated with completely clogged filters. Motor Compensation Feature The Arm-Evac 250 features intelligent pump flow sensors that increase the power to the motor as filters become blocked to assure peak performance. Maintenance General Tips: •...
  • Page 12 Arm correctly attachment connection. If the unit does not work after checking the above, please contact PACE, or your Authorized PACE Distributor if outside U.S. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13: Replacement Filter Part Number

    Replacement Filter part numbers Item # Name Description Typical Applications Part Number Arm-Evac 250 Used with all Arm-Evac 8883-0111P5 Pre-filter Designed for coarse particle capture. 105 systems. (Pkg. Of 5) Soldering, Pharmaceuticals, Laser Arm-Evac 250 Cutting/Laser Marking, General Comprised of HEPA filter media &...
  • Page 14: Pace Worldwide Warranty

    Warranty service may be obtained by contacting the appropriate PACE Company or local Authorised PACE distributor as set forth below to determine if return of any item is required, of if repairs can be made by the user in the field.
  • Page 15: Equipment Warranty Registration

    PACE Incorporated retains the right to make changes to the terms contained herein at any time, without notice. To register your purchase with PACE, fill in the form below and mail or FAX to the applicable PACE address listed above.
  • Page 16 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...