6 Setup
Mode adjustment (2)
Signal lamp (5)
Mode max.
Overflow protection
Mode max.
Overflow protection
Mode min.
Dry run protection
Mode min.
Dry run protection
Failure of the supply volt-
age
(min./max. mode)
20
VEGAVIB 63 will be more sensitive and light solids can be detected
more reliably.
For instruments detecting solids in water, these settings are not ap-
plicable. The density range is preset and must not be changed.
With the mode switch (min./max.) you can change the switching sta-
tus of the transistor output. You can set the required mode according
to the "Function table" (max. - max. detection or overflow protection,
min. - min. detection or dry run protection).
We recommend connecting according to the idle current principle
(switching output is opened when the switching point is reached) be-
cause the transistor output takes on the same (safe) state if a failure
is detected.
Control lamp for indication of the switching status
Green = Output closed
Red = Output open
red (flashing) = failure
6.3

Function table

The following table provides an overview of the switching conditions
depending on the set mode and the level.
Level
any
Switching status
closed
open
closed
open
open
VEGAVIB 63 • Transistor (NPN/PNP)
Control lamp
Green
Red
Green
Red