4.Trouble Shooting

4-1 Troubleshooting

Symptom
Indication
Machine does
Either of the start lamp
not start.
or reset lamp lights.
No lamps light.
Standby lamp lights.
Only power lamp
light.
Start lamp lights.
Roughening cutter
monitor lamp lights.
No lamps light.
Binding cannot
Start lamp does not
light.
be restarted.
Machine cannot
Reset lamp lights.
be reset.
Standby lamp lights.
No lamps light.
Roughening cutter
monitor lamp and
reset lamp light.
Cause
Stop button was
pressed.
Power supply is tempo-
rarily shut off.
Standby mode is set.
Standby switch was
pressed.
Roughening guides are
open.
Roughening cutter
stopped at middle of
two roughening cutter
guides.
Some circuit breakers
(Q01,Q02,Q04) are off.
Cover setting is not
correct, or cover is too
small.
Guard plate is tilted.
Sheets remain in
clamper.
Roughening guides are
open.
Standby mode is set.
Power supply is tempo-
rarily shut off.
Standby switch was
pressed.
Roughening cutter
stopped at middle of
two roughening cutter
guides.
34
Remedy
Release stop button.
Wait for a while.
Press standby switch and wait
for a while.
Wait for a while.
Close roughening guides.
Set roughening cutter switch
on and off several times until
monitor lamp goes out.
Reset circuit breaker.
Set cover in proper position (it
must be over sensor).
Reposition guard plate.
Remove sheets in clamper.
Close roughening guides.
Press standby switch and wait
for a while.
Wait for a while.
Set roughening cutter switch
on and off several times until
monitor lamp goes out.