ENGINE STOP CIRCUIT

When the key switch is turned from the ON
position to the OFF position, the signal current
indicating that the key switch is ON stops flowing
from terminal M to terminal #39 of ECM.
ECM unexcited the fuel injection solenoid valve
and the engine is stopped.
From Fuse #9 of
Fuse Box B
From Fuse #15 of
Fuse Box B
To Fuses #7, #9, #15 of
Fuse Box B
NOTE: The illustration shows the current flow
when the timer is working with the key
switch OFF.
SYSTEM / Electrical System
From Fuse #7 of
Fuse Box B
Diode
Diode
ECM Relay
Fuse
(120A)
Fusible
The ECM relay is excited for 30 seconds after the
key switch is OFF by the timer function. Thus,
current flows to terminals #3 and #4 of ECM, and
ECM is kept ON.
After 30 seconds, the timer stops and ECM is
turned OFF.
Key Switch
Battery
Relay
Link
T2-4-18
Fuse Box A
7
8
3
4
39
Fuel Injection
Solenoid Valve
ECM
Battery
T4GD-02-04-018