Fuses (LH 804)
1. Charge controller for the product battery, 40 A
2. Main fuse, 30 A
3. Receiver + Electronic Control Unit (ECU), 5 A
4. Charger for the remote control battery + Electronic
Control Unit (ECU), 20 A
To drain the water separator
1. Remove the drain plug for the water separator.
2. Drain until there is only clean fuel in the bowl.
3. Install the drain plug.
4. Discard the water as chemical waste. Refer to
Disposal on page 25 .
To replace the oil in the eccentric
element
1. To remove the eccentric element (A), do these
steps:
B
A
a) Remove the 14 long socket screws (B).
22
1
2
3
4
C
b) Remove the screw and washer (C) and install a
ring bolt of type M16x1.5 in the hole.
c) Attach lifting equipment to the ring bolt and lift
the eccentric element.
d) Put the eccentric element on a stable surface.
2. Remove the oil from the oil container (D) with an oil
drain pump or equivalent.
3. Clean the oil container.
E
D
4. Clean the threaded holes for the 14 long socket
screws.
5. Clean the surfaces (E) between the eccentric
element and the bottom plate.
6. Fill the oil container with oil. Refer to
on page 26 for the correct type and quantity of oil.
7. Install a new O-ring (F) and apply grease on top of it
to keep it in position.
F
8. Apply a drop of LOCTITE
threaded holes.
9. Lift the eccentric element back into position on the
bottom plate and remove the ring bolt.
10. Tighten the screws (B) crosswise. Tightening torque
250 Nm.
C
B
11. Install the screw and washer (C). Tightening torque
45 Nm.
Technical data
®
N243
in each of the
1177 - 001 - 02.04.2020

Advertisement

loading

This manual is also suitable for:

Lh 804