Troubleshooting - Xantrex RS232-XHR Operating Manual

Internal rs-232 interface for xhr/xfr series programmable dc power supplies
Table of Contents

Advertisement

Operation

Troubleshooting

Troubleshooting
Diagnostic
LEDs
54
WARNING
Exercise caution when using and servicing power supplies. High energy levels can
be stored at the output voltage terminals on all power supplies in normal operation.
In addition, potentially lethal voltages exist in the power circuit and the output
connector of power supplies which are rated at 40V and over. Filter capacitors store
potentially dangerous energy for some time after power is removed.
This section describes the diagnostic LEDs found on the RS-232 interface.
Computer Operating Properly (COP) LEDs The RS-232 interface provides
three diagnostic LEDs, located at CR167, CR166, and CR89 on its PCB. Refer to
Figure 2.3, 'RS-232 Interface PCB" on page 22, for their locations. At present,
these LEDs turn on to signal COP events for the interface's microprocessors. Issue
a RST (reset) command to turn off the diagnostic LEDs.
The green COP LED at circuit designation CR167 indicates that the RS-232
interface microprocessor successfully recovered from a timeout error due to a
communications bus error. The event is transparent to the RS-232 communications
line continues to function normally.
The red COP LED at CR166 indicates that a transparent restart caused by noise in
the master processor circuitry has occurred.
The red COP LED at CR89 indicates that a transparent restart caused by noise in
the slave processor circuitry has occurred.
Operating Manual for RS-232 for XHR/XFR Series Power Supply

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs232-xfrRs232-xfr3

Table of Contents