  • ENGLISH, page 6
making sure that the fan motor
can start from a stationary
position at the minimum voltage
selected.
Once the minimum speed has
been selected, replace the front
cover (3), the nut (2) and the
speed controller knob (1).
Flush mounting models: REB-
1NE and REB-2,5NE (see fig. 1)
The flush mounting models are
similar to the wall mounting
models excepted that they are
provided without the base (5).
They can be fitted in any standard
box.
Follow the same instructions
given for the wall mounting
models to install and adjust the
flush mounting speed controller.

Change of fuse

The speed controllers are
provided with a spare fuse. To
change it, take off the speed
control knob (1) by hand, or
ease gently with a screwdriver
positioned under the knob,
loosen the nut (2) and remove the
front cover (3). Pull out the fuse
support (9), and replace with the
new fuse.
Uses only a rapid ceramic type
fuse.

Technical caracteristic

REB-1N and REB-1NE
Supply voltage:
220-240 V ~ 50 Hz
Maximum current: 1 A
Type of fuses: rapid ceramic fuse
REB-2,5N and REB-2,5NE
Supply voltage:
220-240 V ~ 50 Hz
Maximum current: 2,5 A
Type of fuses: rapid ceramic fuse.