Commissioning
Bosch Rexroth AG, A4... with HS5E pilot control valve/Series 3x, RE 92076-01-B/10.2017

8.1.4 Connection to the control (IndraWorks)

We will assume that IndraWorks has already been installed. If this is not the case,
install IndraWorks as described in manual R911344285. After this, you must connect
the HS5E system to the PC's Ethernet port and modify the (TCP/IPv4) IP address
of the network port to match the IP address range of the HS5E system. The default
address of the HS5E system is 192.168.0.1. If the IP address is wrong, the row
is highlighted in red. After you have configured the network port, you can open
IndraWorks and start a network search:
Fig. 19: Connection selection
By clicking on the OK pushbutton, you can now establish a connection to the
selected system.
If EtherCat or VARAN are activated as the fieldbus system, you can deactivate
them for direct communication with IndraWorks. To do this, click on the
EtherCAT/VARAN Deactivation pushbutton to send the deactivation command. As
an alternative with these bus systems, it is possible to access the HS5E system
via the control's engineering port.
It is advisable to have a second Ethernet port on your PC or laptop for parallel
operation of the Internet, for example.