Commissioning
Bosch Rexroth AG, A4... with HS5E pilot control valve/Series 3x, RE 92076-01-B/10.2017
The individual calibration functions can be started via IndraWorks and the "Pump
controller calibration" dialog.
Fig. 29: Calibration
For calibrating the HS5E control system, the hydraulic fluid must have reached
operating temperature.

8.1.9 Saving parameters

After carrying out commissioning, you should save the parameter set of the HS5E
pilot control valve. If a malfunction occurs, this is the only way to restore the
parameters or transfer them to a replacement valve.