Midco Incinomite J83-DS Installation And Service Instructions Manual

Incinerator gas burner

Advertisement

Quick Links

Installation and Service Instructions
MADE
in the
USA
• In the United States, installation must conform with local codes
or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1-latest edition available from American
National Standard Institute. Further reference should be made
to the recommendation of your fuel supplier.
• In Canada, installation must conform with local codes or in the
absence of local codes, with Installation Codes for Gas Burning
Appliances and Equipment, CGA Standard CAN/CGA 1-B-149.1
or 2.
WARNING: Additions, changes, conversions
and service must be performed by an authorized Midco
representative, service agency or the fuel supplier. Use
only MIDCO specifi ed and approved parts.
• INSTALLER: Inform and demonstrate to the user the correct
operation and maintenance of the gas utilization equipment.
Inform the user of the hazards of storing fl ammable liquids
and vapors in the vicinity of this gas utilization equipment
and remove such hazards. Affi x this manual and associated
literature to the burner.
CODE COMPLIANCE IS THE SOLE
RESPONSIBILITY OF THE INSTALLER.
• USER: Retain this manual for future reference. If other than
routine service or maintenance as described in this manual
and associated literature is required, contact a qualifi ed service
agency. DO NOT ATTEMPT REPAIRS. An inadvertent service
error could result in a dangerous condition.
AVOID ERROR IN PARTS SELECTION. When ordering use complete MIDCO
Part Number and Description. Furnish Burner Model Number, Bill of Material
Number and Serial Number (if available) from the specifi cation plate found on the
product.
IMPORTANT: Availability of parts as well as specifi cations are subject to change
without notice. Please consult factory for item availability.
®
Midco
International Inc.
4140 West Victoria Street
Chicago, Illinois 60646
toll free 866.705.0514
tel
773.604.8700
fax
866.580.8700
web
www.midcointernational.com
e-mail sales@midcointernational.com
SAFETY INFORMATION TERMS: The following terms are used to identify hazards, safety precaution of special notations
and have standard meanings throughout this manual. They are printed in all capital letters using a bold type face as shown
below, and preceded by the exclamation mark symbol. When you see the safety alert symbol and one of the safety information
terms as shown below, be aware of the hazard potential.
DANGER:
Identifi es the most serious hazards which will result in severe personal injury or death.
WARNING:
Signifi es a hazard that could result in personal injury or death.
CAUTION:
Identifi es unsafe practices which would result in minor personal injury or product and property
damage.
Quality Designed for Proven Performance
Incinomite J83-DS
Incinerator Gas Burner
WARNING: If the information in these instructions
is not followed exactly, a fi re or explosion may result,
causing property damage, personal injury or death.
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately phone your gas supplier from another
building. Follow the gas supplier's instructions. If
you cannot reach your gas supplier call the fi re
department.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
BURNER MODEL:
___________________________________
BILL OF MATERIAL
NUMBER:
___________________________________
SERIAL NUMBER #: ___________________________________
WIRING DIAGRAM: ___________________________________
FOR SERVICE CONTACT
Name:
____________________________________________
Address: ____________________________________________
____________________________________________
Phone:
____________________________________________
Date of Installation: ___________________________________
917
8470 23
Printed in USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Incinomite J83-DS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Midco Incinomite J83-DS

  • Page 1 DO NOT ATTEMPT REPAIRS. An inadvertent service error could result in a dangerous condition. Address: ____________________________________________ AVOID ERROR IN PARTS SELECTION. When ordering use complete MIDCO Part Number and Description. Furnish Burner Model Number, Bill of Material ____________________________________________ Number and Serial Number (if available) from the specifi cation plate found on the product.
  • Page 2: Specifi Cations And Installation

    Install the INCINOMITE burner(s) in location(s) specifi ed by the incinerator manufacturer. It should be positioned approximately level with the top of the highest normal load and fi re with or across the draft fl ow. 8470 23 Midco Inc. International...
  • Page 3 Main Gas Port and Nozzle Support is clean and undamaged. If the incinerator is located outdoors, the burner and all of its components, except the Main Manual Shut-Off Valve, must be protected from weather. The Midco ®...
  • Page 4 PROPANE Propane and Natural 3.0 3.5 4.0 4.5 5.0 5.5 NATURAL Gas 1,000 BTU / Cu. Ft. (with 5/8" Main Gas Port) Input in MBH NATURAL Firing Rate in MBH (800 MBH = 800,000 BTU/Hr) 8470 23 Midco International Inc.
  • Page 5 CAUTION: If the test pressure is over 0.5 PSIG, the test must be made without any burner components connected. DANGER: EXPLOSION HAZARD. DO NOT USE OXYGEN FOR PRESSURE TESTING. AN EXPLOSION COULD OCCUR DURING INITIAL START-UP. __________________________________________ SCHEMATIC COMPONENT LAYOUT Figure 3 - Wiring Diagram 8470 23 Midco International Inc.
  • Page 6 Main Gas Input Adjusting Screw (see Figure 4) until the desired input rating is reached (refer to Table 2). Turning of adjustment screw counterclockwise increases gas fl ow; clockwise reduces fl ow. If Main Flame gas pressure requires adjustment, refer to Section V Piping Supply. 8470 23 Midco Inc. International...
  • Page 7: Installation And Service

    Ignitor trouble will be evidenced by failure of main burner ignition. It may cause frequent Electronic Control lockout. Check for dirt in the ignitor air and mixture passageways and check for obstructions in the ignitor ports. Also check electrode adjustments (see Figure 5). Replace any severely burned parts. 8470 23 Midco International Inc.
  • Page 8 The valve is a single function on-off type with automatic closing on current failure. Replace entire valve if valve fails to open when power is applied or if leakage is defected on standby. Automatic Valve __________________________________________ 8470 23 Midco Inc. International...
  • Page 9: Thermal Switch

    WARNING: Explosion hazard. Do not use this device if it gets wet. It can malfunction and cause serious injury or death. Replace any device that has been wet. __________________________________________ 8470 23 Midco International Inc.
  • Page 10: Trouble Chart

    0.5″ W.C. If pressure is on the high negative side of the range, increase the ignitor gas pressure to 4″ or 5″ W.C. b. No fl ame, clean and test ignitor assembly per Section VIII Ignitor and Regulator Assembly. 8470 23 Midco Inc. International...
  • Page 11 E. Input adjuster not set properly VI Gas Fails to A. Defective automatic valve Shut B. High gas pressure Off *Normal low voltage: Motor running - 24 V minimum Automatic valve energized - 21 V minimum __________________________________________ 8470 23 Midco International Inc.
  • Page 12 J83-DS Manual Midco ® International Inc. - 4140 West Victoria Street - Chicago, Illinois 60646 - toll free: 866 705 0514 9001 tel: 773.604.8700 - fax: 866.580.8700 - web: www.midcointernational.com - e-mail: sales@midcointernational.com 8470 23 Printed in USA...

Table of Contents