Description; Technical Specifications - Pentair Fleck 4600 MECH Installer Manual

Hide thumbs Also See for Fleck 4600 MECH:
Table of Contents

Advertisement

Installer manual Fleck 4600 MECH - Description
3

Description

3.1

Technical specifications

Design specifications/ratings
Valve body
Rubber components
Weight (valve with controller)
Recommended operating pressure
Maximum inlet pressure
Hydrostatic test pressure
Water temperature
Water temperature for HW volumetric 1 - 65°C
Water temperature for HW time
clock...
Ambient temperature
Flow rates (3.5 bar inlet - valve only)
Continuous service flow (Δp = 1 bar)
Peak service flow (Δp = 1.7 bar)
Cv*
Kv*
Maximum backwash flow
(Δp = 1.8 bar)
*Cv: Flow rate in gpm across the valve at a pressure drop of 1 psi at 60°F.
3
*Kv: Flow rate in m
/h across the valve at a pressure drop of 1 bar at 16°C.
Valve connections
Tank Thread
Inlet/Outlet
Riser tube
Drain line
Brine line (1650)
Electrical
Power supply
Transformer output voltage
Motor input voltage
Controller input voltage
Controller max. power consumption
14 / 92
Brass
EP or EPDM
2.5 kg
1.4 - 8.6 bar
8.6 bar
20 bar
1 - 43°C
1 - 82°C
5 - 40°C
3
4.5 m
/h
3
5.9 m
/h
5.2 gpm
3
4.5 m
/h
3
1.6 m
/h
2½" - 8NPSM
¾" or 1"
26.7 mm O.D., 1.05" tube
½" O.D.
⅜"
230 VAC, 50/60 Hz, 15 VA
24 VAC, 10 VA max.
24 VAC
24 VAC
5 W
Ref. MKT-IM-027 / C - 12.11.2019