QOM - DRIVE
Connecting &
Connecting and configuring the LINEARdrive 100/S
DMX in +
-
DMX in
DMX in shield
LedSync out +
LedSync out -
LedSync out
shield
Ext in +
-
Ext in
-
DA
+
-
DA
+
~
~
Primary Wiring
Green = Ground
-
DA
+
-
DA
+
Black = Hot
~
White = Neutral
~
Secondary Wiring
-
DA
+
-
DA
+
Red = Red
Green = Green
Blue = Blue
~
White = White
~
Black = +24V
-
+
M
WARNING:
Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing.
CAUTION:
The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and building codes must be observed.
Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs.
© 2020, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
R
G
B
W
Common anode
R
R
R
R
12V / 24V DIP switch
DALI
120-277
L
VAC
N
Configuration
120-277VAC
50-60Hz
R
G
Red = Red
Green = Green
Blue = Blue
White = White
Black = +24V
PRIMARY
SECONDARY
DMX Shield
DMX -
DMX +
Commonly Asked Questions
1) How can I verify my installation?
● Apply AC input, verify display turns on : This confirms AC input wiring
● Run "Visual Test Run" : This verifies wiring of LEDs. Make sure LEDs turning on go in
same order as the test run
2) I don't have a controller yet, how can I keep my lights on?
● Change the mode to "COLR" : This allows to manually set a specific color to be on
● Adjust the Hue or WHIT to achieve the desired color : This sets that specific color
3) My LEDs aren't coming out the right color. They look like white has been added in
● Verify the network resolution "NETW RES" : Default is 8 BT
● Check your DMX programming. Stick controllers come with RGB programs by default.
This will cause RGBW LEDs to show pink vs. red
Control Wiring
DMX connections
DMX in +
DMX in -
_
M
DMX in shield
-
DA
+
-
DA
+
~
~
NOTE: The unit will be factory wired based on the way the unit is ordered.
Only the one applicable control will be prepared.
: DMX shielding wire must be grounded to Earth ground external to power supply.
Instruction
1
2
A
B
W +24V
LED
DMX IN
DMX OUT
To next
power supply
A
B
R G B W+24
R G B W+24
Red
Blue
Green
DALI connections
+
-
DA
+
-
DA
+
~
~
B
DMX +
GND
DMX -
HOT
GND
NEU
_
+
_
+