Download Print this page

Balanced Body Pilates IQ Reformer Setup page 5

Hide thumbs Also See for Pilates IQ Reformer:

Advertisement

IQs with Library Wheels (702-019)
1. Using the 5/32" Allen key, remove the screws at the foot end
of the frame corresponding to the smaller holes in the library
wheel bracket. See figure L. Note: The bracket on the other
side uses the opposite screws.
Figure L
2. Install the bracket, replace
all screws and tighten.
See Figure M. Repeat on
the other side.
INSTALLING AND
ADJUSTING THE
FOOTBAR
1. The IQ footbar can be
adjusted to four positions.
Two positions are created by
installing the footbar in one
of two sets of holes and
another two by reversing
the footbar
(See Figure N).
Note: If you find the footbar knobs difficult to pull out, wiggle
Figure N
Remove these two screws
Footstrap hole
Figure M
the footbar as you pull.
2. To install the footbar, pull one of the footbar knobs away from
the frame and rotate it 90 degrees and release it. Now it is
locked in the OUT position. Repeat on the other footbar knob
on the other side of the frame.
3. Insert the footbar into the desired holes, facing toward or
away from the carriage, to achieve your desired footbar
position.
MAKE SURE THE FOOTBAR DROPS IN LEVEL AND
EVENLY SO THAT BOTH SIDES GO TO THE BOTTOM OF
THE HOLE. YOU MAY HAVE TO PUSH IT DOWN INTO
THE HOLES.
4. Now turn the footbar knobs either way, until they
automatically lock into place.
5. Grasp the footbar and push and pull it to make sure it is
firmly locked into position.
The knob is locked
in the OUT position
Figure O
6. If the knob is correctly locked, it should only stick out slightly
further than it did when it was fully retracted.
The knob is in the
LOCKED position
Figure P
5

Advertisement