2

Operation

2 .1

Physical Description

Length
Width
Height
Weight
Shipping Weight
Mounting Holes
2 .2

Unpacking, Assembly and Mounting

Tools Required:
1
DC Voltmeter accurate to 0.1V.
2
Small adjustable wrenches that will open to 16mm (5/8 inch).
1
Flat head screwdriver.
4
#1/4-20 bolts & nuts for mounting.
1
Phillips Screwdriver.
Unpack the 5120 TEG from its shipping crate. Keep the crate until the TEG is operational.
Check the TEG for damage which may have occurred during shipping. Any damage must be
reported as soon as possible. The damage may make the generator inoperable therefore,
Check with Global Power Technologies (GPT) Customer Service before starting a dam-
aged TEG .
Locate and identify the following items that were shipped with the 5120 TEG.
1
1 Fin Duct.
1
Intake Stack with Clamp.
1
Exhaust Stack with Clamp.
1
Thread Sealing Compound.
7
#8 - 32 x ¼ inch long Screws (1 spare).
7
#8 Washers, external lock.
Assemble the TEG as follows (see Figure 2):
1)
Attach the fin duct using the #8 screws and washers supplied.
2)
Insert the intake and exhaust stacks into the top of the cabinet.
3)
Slide the clamps over the bottoms of each stack and tighten the clamp screws.
Global Power Technologies
5120
5120 Dimension Chart
757 mm (29.8 in.)
370 mm (14.6 in.)
987 mm (38.9 in.)
267 mm X 457 mm (10.50 wide X 18.00 deep)
60 kg (132 lb)
79 kg (175 lb)
2-1