dymax WIDECURE 41245-L User Manual

Uv light-curing conveyor system

Advertisement

Quick Links

®
WIDECURE
UV Light-Curing Conveyor
System User Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WIDECURE 41245-L and is the answer not in the manual?

Questions and answers

Summary of Contents for dymax WIDECURE 41245-L

  • Page 1 ® WIDECURE UV Light-Curing Conveyor System User Guide...
  • Page 2 Please note that most dispensing and curing system applications are unique. Dymax does not warrant the fitness of the product for the intended application. Any warranty applicable to the product, its application, and use is strictly limited to that contained in the Dymax standard Conditions of Sale.
  • Page 3: Table Of Contents

    Where to Get Help ................................4 Safety ....................................4 General Safety Considerations .............................. 4 Specific Safety Considerations .............................. 4 Dymax Light-Curing System Safety Considerations ....................... 5 Unpacking .................................... 7 Inspecting Your Shipment ..............................7 Unpacking Your Shipment..............................7 Product Overview .................................. 8 Description of the WIDECURE Conveyor ..........................
  • Page 4: Introduction

    To learn about the safe handling and use of light-curable formulations, obtain and read the SDS for each product. Dymax includes an SDS with each adhesive sold. In addition, fluid product SDS can be requested on the Dymax website.
  • Page 5: Dymax Light-Curing System Safety Considerations

    UV Exposure Standard Dymax UV light-curing systems and bulbs have been designed to primarily emit UVA light (Figure 1). UVA light is generally considered the safest of the three UV ranges: UVA, UVB, and UVC. Although OSHA does not currently regulate ultraviolet light exposure in the workplace, the American Conference of Governmental Industrial Hygienists (ACGIH) does recommend Threshold Limit Values (TLVs) for ultraviolet light.
  • Page 6 Ozone Standard Dymax bulbs (UVA type) generate an insignificant amount of UVC and therefore essentially no ozone. Some UV light- curing systems, like those used to cure UV inks, emit primarily “shortwave” (UVB and UVC) energy. Upon exposure to UVC light (specifically <240 nm), oxygen molecules (O2) split into oxygen atoms (O) and recombine with O2 to create ozone O3.
  • Page 7: Unpacking

    Contact Dymax so that new parts can be shipped to you immediately. Check that the parts included in your order match those listed below. If parts are missing, contact your local Dymax representative or Dymax Customer Support to resolve the problem.
  • Page 8: Product Overview

    7. Reattach the Bottom Panel to the front of the machine. 8. Remove the Foam Shipping Blocks that supported the Lamps during shipping. Figure 2. Front Bottom Panel for Access to Forklift Pockets Product Overview Description of the WIDECURE Conveyor The WIDECURE conveyor system is designed to offer consistent, fast, and safe curing.
  • Page 9: Main Components

    Integrated Cooling System – After the lamp is turned off, there is a 5-minute time off delay on the irradiator cooling fans. Do not turn off main power to the system until this 5-minute delay has elapsed. Failure to wait can cause damage to the irradiator cooling assembly or the UV lamp.
  • Page 10: Installation And Interconnection

    Conveyor Setup Installation and Interconnection Your WIDECURE UV light-curing conveyor system requires minimal assembly once removed from the packing skid or crate. 1. A certified electrician should provide 460 VAC, 3Ø, 60Hz, 30A supply. The junction box on the right side of the system contains four #8 AWG MTW wires.
  • Page 11 Figure 6. Irradiator 4. The curing chamber is surrounded by an enclosure, and has a perforated screen on top. Adjustable panels are located on the infeed and outfeed openings of the cure chamber area. Slide the panels up and down to allow for clearance of the parts being run, but low enough to reduce stray light emissions from these openings.
  • Page 12: Operating The Conveyor

    Figure 9. Mesh Plate Gap Operating the Conveyor Using the Main Power Switch located on the Front Panel, turn on the main power to the conveyor (Figure 10). Press the Reset Switch on the Front Panel to turn on the Safety Relays. Figure 10.
  • Page 13: Safety & E-Stop Conditions

    Figure 11. Main Operating Screen Press “Start System” to turn on the Conveyor, UV Lamp, Exhaust Blower, and Irradiator Fans. The UV Lamp will begin warming up and the power level will increase. Do not run parts through the Conveyor until the Indicator (Figure 11;...
  • Page 14: System Adjustments

    System Adjustments Engineering Screen From the Main Operating Screen (Figure 11), the Main Engineering Screen can be reached by pressing the blue engineering button centered at the top of the screen. From the Main Engineering Screen you can access various sub screens: conveyor belt settings, UV lamp settings, and panel configuration.
  • Page 15: Uv Lamp Settings

    Figure 13. Conveyor Belt Sub Screen UV Lamp Settings The UV Lamp Settings Sub Screen (Figure 14) shows the status of the lamp driver. This includes the current lamp power, voltage, and amperage, as well as the fan speed of each of the three irradiator fans. Diagnostic test buttons allow the operator to run the irradiator fans independent of the machine at any set speed.
  • Page 16: Stage

    The elapsed time is displayed next to it. When the elapsed time equals the bulb life setting, a message to change the lamp will appear. After replacing the lamp, press “Lamp Timer Reset” to reset the elapsed time. A 750-hour bulb life is expected from Dymax lamps. Stage The Stage is the lamp lift assembly containing the bulb, also known as the irradiator.
  • Page 17: Maintenance

    • Changing the panel’s IP address • Changing the system’s date, time, and time zone Under normal circumstances, going into the panel configuration is not necessary and not recommended. If the need arises, please refer to the panel’s instruction manual for more specific instructions. Figure 16.
  • Page 18: Belt-Tracking Adjustment

    Belt-Tracking Adjustment All Dymax WIDECURE conveyors are factory adjusted to provide proper tracking of the belt. Should further adjustments become necessary, this is done via two adjustment bolts located at the input end of the conveyor (Figure 17). To adjust tracking, simply tighten the side to which the belt is tracking.
  • Page 19: Bulb Replacement

    Figure 19. Remove Black Panel on Left Side of Conveyor On the right side of the opening, towards the front of the conveyor, is a black-louvered fan cover. This cover can be removed by placing a flat-blade screw driver between the cover and the electrical housing and lifting the cover away from the housing (Figure 20).
  • Page 20: Lamp Stage Care

    From the UV screen, press move to change the lamp position. After the lamp finishes moving, turn off the main power to the system. Lock out the power interlock and circuit breaker feeding the machine. Open the irradiator access door and remove both the fan and irradiator power cables. Pull the yellow tabs on the drawer slides to pull out the irradiator assembly.
  • Page 21 It is not necessary to remove any of the lubrication on the lead screw (Figure 22) unless it appears to be very dirty from the collection of airborne particulate. Removing any buildup of lubrication at either end of the lead screw is advisable. The two guide bars (Figure 22) should be cleaned using a new, clean cloth.
  • Page 22: Troubleshooting

    Troubleshooting Only qualified maintenance personnel should attempt the following procedures. WARNING! Table 1. Troubleshooting Chart Problem Possible Cause Testing Corrective Action Conveyor Not Main Line Circuit Breaker Toggle Power Switch off, then on. Find cause of tripped breaker. Operating tripped. Improperly fastened electrical Check all connections.
  • Page 23: Hmi Alarm Messages

    Ensure there is adequate ventilation and the power supply’s overheating. cooling fans are not restricted. The UV lamp temperature sensor has TempTrip Contact Dymax. malfunctioned. Timer Alarm The UV lamp has reached its Replace the bulb. Instructions for bulb replacement can be expected life.
  • Page 24: Stage Errors

    Stage Errors The stage is controlled by an open-loop stepper motor. From time to time, the stage may lose count of the steps taken, and consequently, its distance from the limit switches. If this happens, please follow the steps below to remediate the problem: If during a move the machine begins to dither (stutter, or a grinding sound) one of two things will happen: •...
  • Page 25: Spare Parts And Accessories

    UVB/UVC) bulb. Longwave bulbs are recommended for most Dymax UV light-curable materials while shortwave bulbs are generally recommended for UV inks. Error! Reference source not found. and Error! Reference source not found. show the spectral distribution of each type of bulb. Unless otherwise specified, Dymax WIDECURE Conveyors are outfitted with longwave (metal- halide) bulbs.
  • Page 26: Specifications

    Specifications System Specifications Property Specification Belt Travel (Left to Right) 41245-L Part Number Belt Travel (Right to Left) 41245-R Bulb Curing Width 25" [63.5 cm] Peak Intensity 700 mW/cm nominal UV-Curing Bulb Life 750 hours typical Information UV Lamp Type 400 W/in metal halide bulb (standard) Reflector Type Focused...
  • Page 27: Definition Of Terms

    Ultraviolet (UV) - The invisible region of the spectrum just beyond the violet end of the visible region. Wavelength ranges in general from 1.0 to 400 nm. Dymax bulbs do not radiate energy in deep ultraviolet; there are very minute amounts below 220 nm.
  • Page 28: Warranty

    Warranty From date of purchase, Dymax Corporation offers a one-year warranty against defects in material and workmanship on all system components (excluding LED array) with proof of purchase and purchase date. Unauthorized repair, modification, or improper use of equipment may void your warranty benefits. The use of aftermarket replacement parts not supplied or approved by Dymax Corporation will void any effective warranties and may result in damage to the equipment.
  • Page 29: Index

    Index Belt Tension Adjustment, 19 Product Overview, 9 Belt Tracking Adjustment, 19 Safety, 4 Bulb Replacement, 21 Safety of UV Light Conveyor Belt Settings, 15 Bright Visible Light, 7 High-Temperature Surfaces, 7 Curing System Safety, 5 UV Exposure, 5 Damaged Parts, 7, 8 Set Up, 11 Definition of Terms, 29 Spare Parts and Accessories, 27...
  • Page 30 © 2017-2020 Dymax Corporation. All rights reserved. All trademarks in this guide, except where noted, are the property of, or used under license by Dymax Corporation, U.S.A. Please note that most curing system applications are unique. Dymax does not warrant the fitness of the product for the intended application. Any warranty applicable to the product, its application and use is strictly limited to that contained in Dymax’s standard Conditions of Sale.