GE AF-650 GP Design And Installation Manual page 59

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Application Setup Examples
CAUTION
Thermistors must use reinforced or double insulation to
meet PELV insulation requirements.
6
6
Table 6.10 Motor Thermistor
6-4
TM
AF-650 GP
Design and Installation Guide
Parameters
Function
Setting
F-10 Electronic
[2]
Overload
Thermistor
trip
F-12 Motor
[1] Analog
Thermistor Input
input 53
* = Default Value
Notes/comments:
If only a warning is desired,
F-10 Electronic Overload should
be set to [1] Thermistor warning.
Table 6.11 Mechanical Brake Control
Figure 6.4
In the upper right corner of the keypad, two numbers are
shown, e.g. 1(1). The number outside the parenthesis is the
active setup and the number inside the parenthesis is the
setup which will be edited. Default will always be 1(1).
Make sure you edit setup 1.
DET-767A
Parameters
Function
Setting
E-24 Function
[32] Mech.
Relay
brake ctrl.
E-01 Terminal 18
[8] Start*
Digital Input
E-02 Terminal 19
[11] Start
Digital Input
reversing
F-24 Holding
0.2
Time
F-25 Start
[5] Advanced
Function
Vector
Control/FLUX
Clockwise
F-29 Start
Im,n
Current
B-20 Release
Application
Brake Current
dependent
B-21 Activate
Half of
Brake Speed
nominal slip
[RPM]
of the motor
* = Default Value
Notes/comments:

Advertisement

Table of Contents
loading

Table of Contents