Troubleshooting
Problem
The refilling pump stalls and
pressurized, but it is not filling the
tank.
Technical Specifications
Compact Dyna-Star Electric Pump
Maximum Working Pressure
Materials of Construction
California Proposition 65
WARNING: This product can expose you to chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm. For more information, go to
www.P65warnings.ca.gov.
3A6932B
1. Follow Pressure Relief Procedure, page 5, before
checking or repairing the pump.
Cause
The Auto-Fill Shut Off valve is in the
closed position and has not been
reset.
The filter (CC) in the refilling line
(GG) is clogged.
1. Disconnect the refilling line.
2. Pull and hold the fill valve
pressure relief knob (FF) long
enough to relieve line pressure
between the fill valve (EE) and
the Auto-Fill Shut Off valve (V)
and between the remote fill
station pump (AA) and the fill
valve (EE).
3. Verify the valve pin is down. See
Fill/Refill the Tank, page 11.
Remove and clean the filter (CC). If
the filter is damaged, replace with a
new filter.
US
3500 psi
zinc plated steel parts, buna-N, polyethylene,
PTFE, fluoroelastomer
Troubleshooting
Solution
Metric
24.1 MPa, 241.3 bar
13