This remote control system must be installed exactly as outlined in these instructions. Read all instructions completely before attempt-
ing installation. Follow instructions carefully during installation. Any modifications of this remote control or any of its components will
void the warranty and may pose a fire hazard.
Do not connect any gas valve or electronic module directly to 110-120VAC power. Consult gas appliance manufacturer's instructions
and wiring schematics for proper placement of all wires. All electronic modules are to be wired to manufacturer's specifications.
The following wiring diagrams are for illustration purpose only. Follow instructions from manufacturer of gas valve and/or electronic
module for correct wiring procedures. Improper installation of electric components can cause damage to electronic module, gas valve
and remote receiver.

INSTALLATION

Before installation make sure the remote receiver slide switch is in
the OFF position. After installation be sure that the slide switch is
moved to the REMOTE position.
MOUNTING THE REMOTE RECEIVER
HEARTH MOUNT
The remote receiver can be placed on the fireplace hearth or under the fire-
place behind the control access panel.
MAKE SURE THAT WHERE THE RECEIVER IS PLACED DOES NOT
EXCEED 170ºF. IT WILL CAUSE DAMAGE TO THE PRODUCT.
Use the wires attached to the remote receiver to connect to the gas valve or
the electric module.
Be sure that the connectors do not touch each other or other bare metal
surfaces; this will cause the appliance to turn on. The connectors may be
wrapped with electrical tape to prevent this.
WIRING INSTRUCTIONS
WIRING MILLIVOLT VALVES
REMOTE
RECEIVER
FAN OUTLET
WIRING ELECTRONIC SPARK IGNITIONS
I
S
Electronic
Module
Skytech: RCTS-MLT-IV
A qualified electrician should install the remote control system.
TERMINAL BLOCK
ON MILLIVOLT
GAS VALVES
TH
TP
TP
TH
THERMOPILE/
PILOT LIGHT
Piggyback
Connectors
Switch
Wires
WARNING
Connect one wire from the remote receiver valve connection to
the TH terminal on the gas valve.
Connect the other wire from the remote receiver valve
connection to the TH/TP terminal on the gas valve.
MILLIVOLT SYSTEM CHECK
Ensure that the pilot flame is lit.
Slide the 3-position button on the remote receiver to the ON
position. The main gas flame (i.e., the fire) should ignite.
Slide the button to OFF. The main flame should extinguish (the
pilot flame will remain on).
Slide the button to REMOTE, then select ON with the mode
button on the transmitter to change the system to on. The main
gas flame should ignite.
FAN
OUTLET
REMOTE
RECEIVER
Fan Outlet Back
Side of RX
Take both switch/thermostatic wires from the
Electronic Module, and connect them to the
receiver wires using the spade connectors.
NOTE: An adapter may be necessary
to make the connection between the
Electronic
Module and the Remote
Receiver.
REV. 3-19-20 Page 3