FIGURE #2
INSTALLING OPTIONAL FAN/BLOWER
Plug 2 or 3 prong fan cord directly into the 3 prong polarized plug on the back
of the receiver (see Figure 3). This receptacle output is 110/120 VAC, 3 AMP.
COMMUNICATION - SAFETY - TRANSMITTER - (C/S - T/X)
This remote control has a COMMUNICATION –SAFETY function built into its soft-
ware to ensure the transmitter and receiver are communicating normally.
In all operating modes, the transmitter sends an RF signal every fifteen minutes to
the receiver indicating that the transmitter is within the normal operating range of
20-feet. Should the receiver NOT receive this signal, the receiver will begin a 2-hour
countdown. If the receiver does not receive a signal from the transmitter in 2-hours,
the receiver will shut off the appliance. The receiver will then emit a series of rapid
"beeps" for a period of 10 seconds. Then after 10 seconds of rapid beeping, the re-
ceiver will continue to emit a single "beep" every 2 seconds until a transmitter MODE
Button is pressed to reset the receiver.
AUTO SHUT DOWN
This remote control has an auto shut down feature incorporated into its system. When the transmitter mode is in the ON position, the
appliance will only run for 9 hours. After that it will shut down. To reactivate the appliance, press the MODE button.
CP (CHILDPROOF) FEATURE
This remote control includes a childproof feature that allows the user to "lock-out" operations from the transmitter.
To activate and de-activate the childproof feature, press and hold the SETTING button behind the battery cover, for 5 seconds
(SEE The letters "CP" will briefly appear on the LCD screen when childproof mode is activated).
"CP" will appear on the LCD screen if any button is pressed while childproof mode is engaged.
When this mode is engaged, all auto settings go on without interruption (like thermostat). Only manual functions are prevented.