Troubleshooting Assistance Guide
Programming
(continued)
38
Thermostat does not follow programmed times.
•
The thermostat has an intelligent algorithm (Energy Recovery Management) that
automatically starts the heating/cooling system before the scheduled start time so that
the desired temperature is reached at the scheduled start time.
•
The thermostat maybe set in the Hold (override) mode. Press RUN to reset the hold
and go back to the programmed setpoint.
•
Recheck program for current setting versus the program settings.
•
Make sure AM and PM are correct for each period in the program.
In program mode, the time or temperature displays "--".
Display of dashes (- -) during programming means that there are different values
programmed into the days within the selected group of days. For example, if you are
programming the weekdays (Monday – Friday) together as a group and Monday has a
different setpoint or start time, the display will show the dashes in the respective locations.
To overwrite the value so that all days are the same, simply press the TIME/SET button
until the right element (time or setpoint) is flashing, press the UP/DOWN arrow buttons to
set the value. This will overwrite the entire group to the same value.
SuperStat Pro User Guide
Need help?
Do you have a question about the SuperStat Pro SuperStat Pro Programmable Thermostat and is the answer not in the manual?