Racewell HD
Compressor
The following specification is required for your Racewell Handler:
12 CFM capacity
If your compressor lower capacity than these specification then the Racewell may work slowly.
Manufacturer installation and maintenance guidlines for the compressor should be followed.
This includes checking the oil and draining water from the tank.
Please note: when turning the compressor on or off use the switch on the compressor
and not the switch at the power source.
Attaching the air fittings and connecting the compressor
From your Compressor
Power Supply
4
S H E E P H A N D L I N G S YS TE M S
Minimum pressure of 90 psi
1 m / 3 feet
(approx)
Ball or tap valve
Connect the air line to the Racewell handler. The connection
is located underneath the Clamp and Weigh Area. If the
compressor is located some distance away from the racewell
handler it is recommended that you include a water trap on the
line to avoid condensation getting to the handler pneumatics.
The image above shows a design for a simple water trap.
To your Racewell
Power can be supplied via
mains (110V AC to 240V AC)
or via the 12 Volt battery leads
supplied with the handler. The
internal system is all 12 Volt AC
power supply.
Te Pari Racewell HD3, HD4 & HD6 Operators Manual