Fronius Acctiva Easy 1202 Operating Instructions Manual page 36

Battery charging system
Hide thumbs Also See for Acctiva Easy 1202:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
Safety cut-out
If the battery does not reach a predefined voltage level within a given period, the charger
switches off. Please refer to "Technical data" for the safety cut-out time.
What to do in the event of a safety cut-out:
1
2
3
4
Cause:
Remedy:
Cause:
Remedy:
Cause
:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Symbols on rat-
These symbols will also be found on the rating plate in addition to the safety symbols:
ing plate
36
Unplug the device from the grid
Disconnect battery
Determine cause of safety cut-out
Rectify error and restart charging if necessary
These symbols are displayed alternately
Battery too large
Restart charging
Active accessories using too much power
Switch off accessories and restart charging
Faulty battery (e.g. cell short circuit, smell of gas, differing cell tempera-
tures, housing deformation, different liquid levels or liquid leaking, etc.)
Check battery. Do not continue the charging process under any circum-
stances
Selector switch incorrectly set
Correct selector switch setting and restart charging
Incorrect device type for this application
Check battery and charger and ensure they are compatible
Read operating instructions before charging.
Avoid flames and sparks during charging.
Caution! Explosive gases given off during charging.
Battery acid is corrosive.
For indoor use only. Do not expose to rain.
Ensure adequate ventilation during charging.