  • ENGLISH, page 21
Connecting/dis-
connecting the
battery
Danger due to connecting or disconnecting the battery while the charger is connect-
ed to the grid.
This can result in serious injury and damage to property due to short circuits and arcs.
► Before connecting/disconnecting the battery, disconnect the charger from the grid.
► During operation, check that charging terminals and battery poles are properly con-
Establish a connection as follows:
1
2
3
4
Danger due to incorrect battery disconnection sequence.
This can result in serious injury and damage to property due to short circuits and arcs.
► When disconnecting, it is imperative to follow the above instructions in the reverse or-
If using an on-board or system plug to connect the charging lead, steps 3 and 4 do not ap-
ply. Instead, connect charging lead to a suitable on-board socket.
28
WARNING!
nected.
Unplug the device from the grid
Plug charging lead into charger connection socket
Connect (+) charging terminal to positive pole (red) on battery
Connect (-) charging terminal to negative pole (black) on the battery, or to vehicle body
(e.g. engine block) in the case of vehicle power supplies.
WARNING!
der to avoid short circuits and arcs.