Charging
General
Danger due to connecting or disconnecting the battery while the charger is connect-
ed to the grid.
This can result in serious injury and damage to property.
► Before connecting/disconnecting the battery, disconnect the charger from the grid.
► During operation, check that charging terminals and battery poles are properly con-
Danger if battery is not monitored.
This can result in serious injury and damage to property due to short circuits, arcs and ox-
yhydrogen explosions.
► Carry out a visual inspection at least once a week or as often as specified by the battery
► If any of the following occur, do not start the device (or stop immediately if already in
Danger from attempting to charge a faulty battery.
This can result in damage to property.
► Before charging, ensure that the battery to be charged is fully functional.
Charging the bat-
To start charging, proceed as follows:
tery
1
2
3
4
5
6
7
32
WARNING!
nected.
WARNING!
manufacturer to ensure that the acid level in the battery is at the Max. mark.
use) and have the battery checked by an authorised workshop:
uneven acid levels and/or high water consumption in individual cells,
overheating of the battery above 55 °C (131 °F).
NOTE!
Switch off engine and ignition, switch off all consumers.
Set the selector switch to the correct position (see "Setting the selector switch")
Establish connection to battery
Charger displays battery open circuit voltage
Connect charger to grid
Charger starts to charge
Charger displays current state of charge as a sequence of bars
0%
20%
50%
80%
100%