Advanced Settings Of Driver Parameters; Restore The Multi-Path Connection - Fujitsu PRIMEQUEST 2000 Series Manual

Configuring the san boot environment
Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

Consideration of Linux Installation

5.1.3 Advanced settings of driver parameters

Make various settings by referring to CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 2000) or
CHAPTER 6
Work after Operating System Installation (PRIMEQUEST 2000) in the PRIMEQUEST 2000 Series Installation Manual
(C92344-0536).
5.1.4 Install OCManager
1.
Install OCManager.
2.
If you install OCManager, you will need lib pakeage. Install libnl pakeage.
Get FC card driver/Utility and install "OCManager". OCManager includes Libnl pakeage.
3.
Copy the binary files on the PRIMEQUEST 2000 series optional directory
4.
Refer to install procedure of OEM Driver Installation about how to install OCManager
5.
Remarks
One side FC cable is still take off the connector at this point.
5.1.5 Install multi-path driver
Install Multi-path driver the multi-pass driver that uses it is installed.
Refer to the manual of the multi-pass driver that uses it for the installation procedure.

5.1.6 Restore the multi-path connection

Recover multi-pass connection.
OS is shutdown, the cable of the FC passing cut according to procedure 1 is reconnected after the power supply of
the partition is cut, and OS is started. After it shuts down after the start by the multi-pass is confirmed, internal HDD
into is added when internal HDD into is used.
Remarks
Confirm multi-pass status with the following process.
1.
Set UEFI driver on HBA system.
(Refer to Chapter 2 Fibre channel setting (8Gbps FC card) and Chapter 2 Fibre channel setting (16Gbps FC
card))
Run Boot Manager front page and [Boot Maintenance Manger] - [Boot Options] - [Set
2.
HardDiskDriverOrder]
Confirm the following screen.
3.
C122-E206-04EN
104
Legacy