Troubleshooting - Bosch DLR165 Operating/Safety Instructions Manual

Digital laser rangefinder
Table of Contents

Advertisement

Available languages

Available languages

BM 2609140573 04-08
Slide the latch 15 of the extension pin sideward
in order to swivel out the pin.
Set the corresponding reference point for
measurements with the extension pin by
pushing button 10.
The extension pin 14 swivels back in again by
pushing it toward the housing to the stop. The
pin automatically locks in place.
Working with Tripod
The use of a tripod (not included) is particularly
advisable for larger distances because of the
Issue
The indications "Hot" or "Cold" are indicated in the display; measurement not possible.
The measuring tool is not within the operating
temperature of – 10 °C to +50 °C
(+14 °F to +122 °F).
Battery voltage decreasing
(measurement still possible)
Battery indication a flashes, measurement not possible
Battery voltage too low
The indications "Err." and "- - -" are indicated in the display
The angle between the laser beam and
the target is too acute.
The target surface reflects too intensely
(e.g. a mirror) or insufficiently (e.g.
black fabric), or the ambient light
is too bright
The laser beam outlet 19 or the
reception lens 20 are misted up (e.g.
due to a rapid temperature change).
The calculated area or volume value
is larger than 99990 ft
Addition/Subtraction of different
types of measurements
The target surface does not reflect
correctly (e.g. water, glass).
The laser beam outlet 19 or the
reception lens 20 are covered.
4/15/08
3:11 PM
Trouble Shooting
Battery indication a is indicated
2
3
or ft
.
The indication "Err." flashes at the top in the display
Unreliable measuring result
Page 12
steadiness it provides. The rangefinder tool
can be screwed onto a commercially available
tripod using the 1/4" thread 21 on the bottom
side of the housing.
Set the corresponding reference point for
measurement with a tripod by pushing button
10 (the reference point is the center of thread).
Remedy
Wait until the measuring tool has reached the
operating temperature
Replace batteries
Replace batteries
Enlarge the angle between the laser beam
and the target
Work with the laser target plate 23
(optional accessory)
Wipe the laser beam outlet 19 and/or the
reception lens 20 dry using a soft cloth
Change unit of measure to "m"
Only add/subtract of the same type
Cover off the target surface
Make sure that the laser beam outlet 19 or
the reception lens 20 are unobstructed
-12-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dlr165k

Table of Contents