8 TEKNISK SPESIFIKASJON

Strømforsyningsspenning U1 (50/60 Hz)
Zmax (@PCC)
Treg linjesikring
Kommunikasjonsbuss
Maksimal effekt absorbert MMA (kVA)
Maksimal effekt absorbert MMA (kW)
Maksimal effekt absorbert TIG (kVA)
Maksimal effekt absorbert TIG (kW)
Maksimal effekt absorbert MIG/MAG (kVA)
Maksimal effekt absorbert MIG/MAG (kW)
Effektfaktor PF
Yteevne (µ)
Cos
Maksimal absorbert strøm I1max
Faktisk strøm I1eff
Bruksfaktor MMA (40°C)
(x=40%)
(x=50%)
(x=60%)
(x=100%)
Bruksfaktor MMA (25°C)
(x=80%)
(x=100%)
Bruksfaktor TIG (40°C)
(x=50%)
(x=60%)
(x=100%)
Bruksfaktor TIG (25°C)
(x=80%)
(x=100%)
Bruksfaktor MIG/MAG (40°C)
(x=40%)
(x=50%)
(x=60%)
(x=100%)
Bruksfaktor MIG/MAG (25°C)
(x=80%)
(x=100%)
Reguleringsområde I2
Tomgangsspenning Uo
Beskyttelsesgrad IP
Isoleringsklasse
Mål (lxdxh)
Vekt
Produksjonsnormer
Nettkabel
Lengde på nettkabel
*
Dette utstyr er i overensstemmelse med EN/IEC 61000-3-11.
*
Dette utstyr samsvarer med EN/IEC 61000-3-12 hvis maximum tillatt nettimpedanse ved grensesnittpunktet til offentlig nett (felles koplings-
punkt, PCC) er mindre eller lik "Zmax" fastsatt verdi. Hvis det koples til et offentlig lavspenningssystem, er det installatørens eller utstyrets
brukers ansvar, ved å konsultere operatøren av forsyningsnettverket om nødvendig, at utstyret kan tilkoples.
URANOS 4000 PME
3x400Vac ±15%
57mΩ *
25A
DIGITAL
16.9 kVA
16.1 kW
12.6 kVA
12.1 kW
16.1 kVA
15.3 kW
0.95
88%
0.99
24.4A
18.9A
-
-
400A
360A
-
400A
-
400A
360A
-
400A
-
-
400A
360A
-
400A
3-400A
73Vdc
IP23S
H
690x290x510 mm
35.2 kg.
EN 60974-1 / EN 60974-10
4x4 mm2
5 m
185