8. Check list for troubleshooting

Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
!
Possible cause: The device is defective. à Return the device for
check.
The PC monitor does not show data.
Possible cause: The connection between the RC-Link and the PC is
interrupted. à Check the connection.
Possible cause: The power supply of the RC-Link is interrupted (and
the LED on the device does not light). à Check the connection to
the power supply.
Possible cause: When installing the software another interface has
been choosen other than the one connected with the RC-Link. à If
necessary alter the interface at the PC.
Possible cause: The connection A of the RC-Link is connected to the
connection B of the detector (or the other way round). à Exchange
the connections A and B at one of the devices.
Possible cause: The booster connected to the controlled rail section
is switched off or does not supply the RailCom cutout. à Check the
booster.
Possible cause: The vehicle decoder in the supervised rail section
does not send a RailCom message, e.g. when in the corresponding
CV the RailCom function is set to off. à Check the vehicle decoder.