tams elektronik 70-01045 Manual

Adapter for plux22- and 21mtc-interface
Hide thumbs Also See for 70-01045:

Advertisement

Quick Links

Adapter for PluX22-
and 21MTC-Interface
Manual
Item number 70-01045
PluX22
NEM 658 | RCN-122
NEM 660 | RCN-121
tams elektronik
n n n

Advertisement

Table of Contents
loading

Summary of Contents for tams elektronik 70-01045

  • Page 1 Adapter for PluX22- and 21MTC-Interface Manual Item number 70-01045 PluX22 NEM 658 | RCN-122 NEM 660 | RCN-121 tams elektronik n n n...
  • Page 2: Table Of Contents

    © Tams Elektronik GmbH All rights reserved, in particular the right of reproduction, distribution and translation. Copies, reproductions and alterations in any form require the written permission of Tams Elektronik GmbH. We reserve the right to make technical changes. Printing the manual The formatting is optimised for double-sided printing.
  • Page 3: Getting Started

    Adapter for PluX22- and 21MTC-Interface 1. Getting started This manual gives step-by-step instructions for safe and correct assembly of the kit and fitting and connecting of the adapter, and operation. Before you start, we advise you to read the whole manual, particularly the chapter on safety instructions and the checklist for trouble shooting.
  • Page 4: Operation Overview

    Adapter for PluX22- and 21MTC-Interface tams elektronik 2. Operation overview The adapter is used to upgrade vehicles with a PluX or MTC interface interface. There is a 22- pole socket soldered on to the adapter PCB which is used to insert the plug connector of the decoder-sided PluX interface.
  • Page 5: Mounting Versions For Plux Decoders

    Adapter for PluX22- and 21MTC-Interface 2.3. Mounting versions for PluX decoders Mounting version 1: Inserting direction of the decoder: from above Mounting version 2: Inserting direction of the decoder: from below 2.4. Mounting versions for MTC decoders Mounting version 1 a:...
  • Page 6: Assembling The Kit

    Adapter for PluX22- and 21MTC-Interface tams elektronik 3. Assembling the kit 3.1. Safety instructions Mechanical hazards Cut wires can have sharp ends and can cause serious injuries. Watch out for sharp edges when you pick up the PCB. Visibly damaged parts can cause unpredictable danger. Do not use damaged parts: recycle and replace them with new ones.
  • Page 7: Safe And Correct Soldering

    Adapter for PluX22- and 21MTC-Interface 3.2. Safe and correct soldering Caution: Incorrect soldering can cause dangers through fires and heat. Avoid these dangers by reading and following the directions given in the chapter Safety instructions.  Use a soldering iron with temperature control, which you set to approx. 300 °C.
  • Page 8: Soldering On The Cables

    Adapter for PluX22- and 21MTC-Interface tams elektronik 3.3. Soldering on the cables Solder the connecting cables on the top side of the adapter PCB. Observe the different assignments for PluX and MTC interfaces and the different mounting versions. It is recommended to use cables of different colours according to NEM 658 or NEM 660 in order to avoid mistakes when connecting the adapter PCB.
  • Page 9 Adapter for PluX22- and 21MTC-Interface Cable Name Description Plux adapter colour GPIO/C Universal input/output AUX3 Output 3 GPIO/B Universal input/output, train-bus pulse GPIO/A Universal input/output, train-bus data Decoder ground, pick-off after rectifier V+ Cap. Decoder plus, pick-off after rectifier,...
  • Page 10: Assignment For 21Mtc Adapters (Nem 660/Rcn-121)

    Adapter for PluX22- and 21MTC-Interface tams elektronik 3.5. Assignment for 21MTC adapters (NEM 660/RCN-121) In order to avoid damage due to a connection of the decoder with reversed polarity, you sould remove the index pin (pin 11) at the 22-pole plug connector. You can withdraw the pin with small pliers.
  • Page 11 Adapter for PluX22- and 21MTC-Interface Cable Name Description MTC adapter colour Input1 Sensor input 1 Input2 Sensor input 2 AUX6 Output 6 AUX4 Output 4 ZBCLK Pulse generator train bus ZBDTA Data train bus (TxD, RxD) Lighting forward direction...
  • Page 12: Checklist For Troubleshooting And Error Correction

    Adapter for PluX22- and 21MTC-Interface tams elektronik 4. Checklist for troubleshooting and error correction Warning: If you notice a strong heat development, immediately disconnect the connection to the supply voltage. Fire hazard! Possible causes:  The connecting cables on the PCB are badly assigned to the connections of the decoder or the vehicle.
  • Page 13: Technical Data

    Adapter for PluX22- and 21MTC-Interface Carrying out the repair(s) By sending in the product(s), you give us the order to inspect and repair it. We reserve the right to refuse the repair if it is technically impossible or uneconomical. In the event of a warranty or guarantee claim, you will then receive a replacement free of charge.
  • Page 14: Warranty, Eu Conformity & Weee

    Adapter for PluX22- and 21MTC-Interface tams elektronik 6. Warranty, EU conformity & WEEE 6.1. Guarantee bond For this product we issue voluntarily a guarantee of 2 years from the date of purchase by the first customer, but in maximum 3 years after the end of series production. The first customer is the consumer first purchasing the product from us, a dealer or another natural or juristic person reselling or mounting the product on the basis of self-employment.
  • Page 15: Eu Declaration Of Conformity

    Adapter for PluX22- and 21MTC-Interface 6.2. EU Declaration of Conformity This product fulfils the requirements of the following EU directives and therefore bears the CE marking. 2001/95/EU Product Safety Directive 2015/863/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 2014/30/EU on electromagnetic compatibility (EMC Directive).
  • Page 16 Further Information and Tips: http://www.tams-online.de Warranty and Service: tams elektronik GmbH Fuhrberger Str. 4 30625 Hannover / GERMANY Phone: +49 (0)511 / 55 60 60 Fax: +49 (0)511 / 55 61 61 Email: support@tams-online.de...

Table of Contents