Installing Generac PWRcell Battery
See
Figure
4-19. Continue connecting the remain-
7.
ing battery modules. While installing CAT5 cables:
•
Work from top to bottom
•
Connect battery modules sharing a shelf with a
black jumper cable (I) going from the rear battery
COM OUT port to the front battery COM IN port
•
Do not install a CAT5 cable to the last battery
module's COM OUT port (M)
•
Remaining COM cables can be left disconnected.
•
Unused CAT5 jumpers should be kept in safe place
for future module upgrades.
L
I
M
Figure 4-19. Module COM Cabling (2 of 2)
I
Gray CAT5
J
Blue CAT5
K
Orange CAT5
L
Black CAT5 Jumpers
Connecting Battery Power Cable
DANGER
Electrocution. Never reach into port or touch
battery terminals with hands or tools. Doing so
will result in death, serious injury, equipment or
property damage.
See
Figure
4-20. Remove gray rubber cap (A)
1.
from each module power port.
Plug black power cable connectors into battery
2.
module power ports (B).
20
B
See
3.
I
unused power cord connector (D).
J
K
Figure 4-21. Installing Loop Jumper
009941
See
4.
wiring chase baffle slot (F) for future use.
NOTE: If a battery module needs to be replaced, spare
loop jumpers can be used to keep the PWRcell battery
running until the replacement battery module gets
installed.
(000639)
Figure 4-22. Unused Loop Jumpers
Figure 4-20. Power Cable Ports
Figure
4-21. Install loop jumper (C) on every
C
D
Figure
4-22. Tie unused loop jumpers (E) to
Installation Manual for Generac PWRcell Battery
A
009943
F
E
009944