Section 2: General Information; Specifications - Generac Power Systems PWRcell Series Installation Manual

Table of Contents

Advertisement

Section 2: General Information

Specifications

Description
Energy
Usable Energy
Power
*
Continuous
**
60 minutes
**
2 minutes
Battery Modules
Number
DC Voltage (per module)
REbus
Communication Protocol
***
Voltage: Input/Output
Round-Trip Efficiency (DC to DC)
Temperature
Operating Temperature Limits
Recommended Temperature Range
Installation Altitude
Maximum Installation Altitude
Weight
Enclosure
Installed
Compliance
UL
CSA
*
Full cycle: 0% to 100% to 0% SoC @ 30° C
**
Discharge @ 25° C
***
380VDC Nominal
****
Reduced performance at extreme temperatures
*****
Module warranty void if installed above limit
Specifications are subject to change without notice. Refer to the product specification sheet for complete list.
Installation Manual for Generac PWRcell Battery
Units
kWh
kW
kW
kW
-
VDC
-
VDC
%
****
°F (°C)
°F (°C)
*****
ft (m)
lb (kg)
lb (kg)
-
-
PWRcell 9
PWRcell 12
8.6
11.4
3.4
4.5
4.2
5.6
5.0
6.7
3
4
46.8 (39-52)
REbus DC nanogrid
360-420
96.5
41-113 (5-45)
54-86 (13-30)
9834 (3000)
115 (52)
280 (127)
335 (152)
UL 9540, UL 1973, UL 1642,
CSA 22.2
General Information
PWRcell 15
PWRcell 17
14.3
17.1
5.6
6.7
7.0
8.4
8.4
10.0
5
6
390 (178)
445 (202)
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pwrcell 9Pwrcell 12Pwrcell 15Pwrcell 17

Table of Contents