Install Range Hood; Connect Vent System (For Vented Installations Only); Make Electrical Connection - Whirlpool W10029770A Installation Instructions And Use And Care Manual

90 cm (35 ²⁄₅") wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Install Range Hood

WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
1. Using 2 or more people, hang range hood on 2 mounting
hooks through the rectangular cutouts on back of hood.
D
A
F
B
A. Mounting hooks
B. Mounting screws
C. Leveling screws
D. Centerline on wall
2. Level the hood with leveling screws in mounting hooks or
rectangular cutouts, using a level across bottom of hood.
3. Secure hood with 4 screws through remaining 4 holes in
hood.
4. Install transition with 2 screws.
Connect Vent System
(for vented installations only)
1. Fit vent system over transition piece.
A
B
A. Vent system
B. Transition piece
2. Seal connection with clamps.
E
F
G
B
C
E. Transition
F. 3.5 x 9.5 mm screws
G. Terminal box

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install the
UL-listed or CSA approved
4. Run 3 wires, black, white and green (14AWG) in
from service panel to terminal box.
A
C
D
A. UL-listed or CSA
approved strain relief
B. " conduit
C. Terminal box
5. Use UL listed wire connectors and connect black wires
together.
6. Use UL listed wire connectors and connect white wires
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect ground wire to green and yellow ground wire in
terminal box using UL listed wire connectors.
" strain relief.
" conduit
B
F
E
D. Black wires
E. Green (or bare) wire connected
to yellow-green wire
F. White wires
9