Technical Information

Technical Specifications

Steady State Gas
Consumption
Supply Gas
Maximum Flow Capacity
Maximum Supply Pressure
Maximum Supply –
Discharge Differential
Minimum Supply –
Discharge Differential
Operative Ambient
Temperature Range
Approximate Weight
Minimum Deadband
Control Accuracy
Maximum Sensing Pressure
Setpoint Range
Housing
Installation Orientation
VRP-B-175-CH
3 | GE Oil & Gas
<10 scfh when bleeding to atmosphere
When bleeding downstream, see
consumption table in Appendix
Dry, filtered (100 micron) gas
850 scfh (24 scmh)
400 psig (2758 kPa)
150 psig (1034 kPa)
50 psig (348 kPa)
-20°F to 160°F
(-29°C to 71°C)
12 pounds (5.4 kg)
0.2% instrument signal
± 0.75% of setpoint
1500 psig
3 psig – 1500 psig
21 kPa – 10342 kPa
Meets NEMA 3 classification
Vertical position recommended
• Custom bracket supplied with
Becker Actuators
• 2-in pipe mount provided for retrofit to
other manufacturers' actuators
VRP-B-600-CH
VRP-B-CH pilots – model numbers

Materials of Construction

External Parts
AL 2024 Anodized Aluminium/316
Stainless Steel
Internal Parts
316 Stainless Steel/2024 Anodized Aluminum
Springs
Plated steel
Diaphragms
Buna-N with nylon reinforcement
Seats and O-Rings
Buna-N
Tubing and
316 Stainless Steel
Tubing Fittings
Gauges
2-1/2 inch dial liquid filled brass connection w/
stainless steel case
(standard issue with units of psig dual units of
psig/kPa available).
(1)
Consult GE for additional information.

Model Number Explanation

The VRP-B-CH pilot is available in four different models to
cover sensing pressures from 3 psig to 1500 psig.
The number expressed in the VRP model designation is the
maximum sensing pressure (for example, a VRP-B-600-CH
has a maximum sensing pressure of 600 psig).

Identification Tag

Each unit has a stainless steel control tag fastened under one of
the bolts of the spring cartridge. The range of the control spring
is stamped on the face side of the tag. The shipping date and
seven-character part number are stamped on the bottom side
of the tag. The letter after the seven-digit part number identify
the pilot revision series.
VRP-B-1000-CH
© 2016 General Electric Company. All rights reserved.
(1)
VRP-B-1500-CH