Complete Installation; Install Filters; Check Operation - Whirlpool IH7302RS0 Installation Instructions And Use And Care Manual

30" (76.2 cm) wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Complete Installation

1. Install vent cover.
■ When using both upper and lower vent cover, push lower
cover down onto hood and lift upper cover to ceiling and
install screws.
A. Upper vent cover
B. Lower vent cover
■ For reduced ceiling height installations, when using only
the lower cover, push lower cover down onto hood and
snap vent into place around vent cover bracket.

Install Filters

1. For non-vented (recirculating) installations, install charcoal
filter over grill on blower housing and turn filter handle
clockwise. Repeat with other charcoal filter.
A
C
A. Blower housing
B. Handle
C. Charcoal filters
2. For all installations, insert back edge of metal filter into rear
channel of the filter opening.
3. Push handle toward the rear and push filter up.
4. Pull filter toward the front and insert into front channel.
1. Check operation of the range hood by turning the power on.
A
2. Move the light switch to the "1" position. The light should
B
3. Move the light switch to the "0" position. The light should
4. Move the blower switch to the "1" position for low speed.
5. Move the blower switch to the "0" position. The blower
6. If range hood does not operate, check that the circuit breaker
B
C

Check Operation

A
O I
A. Light switch
B. Blower switch
turn on.
turn off.
"2" position for medium speed. "3" position for high speed.
should turn off.
has not been tripped or the house fuse blown. Disconnect
power supply and check that the wiring is correct.
B
O 1 2 3