1. Installation

1-2. Installing the mainframe

Comply with the instructions set forth in "Safety precautions" and also observe
the cautionary items below.
Be absolutely sure to ask your dealer to do the jobs of installing and connecting the mainframe.
Connecting the power supply
p Use within AC 100 V to 120 V.
p Use both power system 1 and power system 2 for operating the mainframe.
An alarm will be displayed if AC power is not supplied to both power system 1 and power system 2 or if the
power switch is at the OFF position.
p Be absolutely sure to use the power cord supplied with the mainframe.
p Be absolutely sure to connect the grounding terminal of the power cord to ground.
Handle the mainframe carefully!
p Dropping the mainframe or subjecting it to strong impact or vibration may cause trouble and/or malfunctioning.
Do not allow any foreign objects to enter inside the mainframe!
p Allowing water, metal items, scraps of food or other foreign objects inside the mainframe may cause a fire and/
or electric shocks.
Choosing the best installation location
p This unit is designed for indoor use only.
p Mount the mainframe securely in a standard 19-inch rack (with a depth dimension of at least 600 mm (23-5/8˝))
that meets the EIA standard or its equivalent for use.
p Install the mainframe securely using screws that are compatible with the rack.
p Be absolutely sure to attach the support guides used to support the back part of the mainframe.
(Provide support guides that are compatible with the rack.)
p Provide sufficient clearances from the area around the ventilation holes at the front and the cooling fan at the
back.
p Do not install the mainframe in a cold place where the temperatures will drop below 0 °C (32 °F) or in a hot
place where the temperatures will rise above 40 °C (104 °F).
p Avoid installing the mainframe where it will be exposed to direct sunlight or to the hot air that is blown out from
other products.
p Installing the mainframe in a very humid, dusty or vibration-prone location may give rise to trouble.
POWE R1
OFF
ON
POWE R1
ALARM 1
Installation in a rack
Support guides
POWE R2
OFF
ON
POWE R2
ALARM 2
Mul ti-fo rma t
Live Swi tche
r AV-H S45 0
Flow of air through the ventilation holes
11
5 0
S 4
2
W ER
V -H
r A
PO
h e
M 2
R 2
O N
it c
W E
AL
AR
P O
S w
iv e
O FF
t L
m a
fo r
lt i-
M u
1
W ER
PO
M 1
R 1
O N
W E
AR
AL
P O
O FF

Advertisement

Table of Contents
loading

Table of Contents