Technical data
14.1 Technical specifications of the CPU 410-5H; (6ES7 410-5HX08-0AB0)
Data areas and their retentivity
Retentive data area, total
Bit memory
Number, max.
Retentivity, available
Number of clock memories
Data blocks
Number, max.
Size, max.
Local data
Can be set, max.
Default
Address range
I/O address range
Inputs
Outputs
of those distributed
DP interface, inputs
DP interface, outputs
PN interface, inputs
PN interface, outputs
Process image
Inputs, can be set
Outputs, can be set
Inputs, preset
Outputs, preset
Consistent data, max.
Access to consistent data in the process image
Process image partitions
Number of process image partitions, max.
Digital channels
Inputs
Outputs
Inputs, central
Outputs, central
Max. number of addressable digital I/O
220
6ES7410-5HX08-0AB0
Total work and load memory (with backup battery)
16384 bytes
Yes
8; in 1 memory byte
16000; number range: 1 to 16000
64 KB
64 KB
64 KB
16 Kbyte; up to 7 500 IO
16 Kbyte; up to 7 500 IO
6 Kbyte; up to 2 800 IO (channels)
6 Kbyte; up to 2 800 IO (channels)
8 Kbyte; up to 3 800 IO (channels)
8 Kbyte; up to 3 800 IO (channels)
16 KB
16 KB
16 KB
16 KB
244 bytes
Yes
15
131072, max.
131072, max.
131072, max.
131072, max.
131072