Connection to the Programmable Controller
alEn lh€ intemal interfacc po\rer source is used
I T}|rs rs an example whcn the sink type transistor
.{Iput (open collector output) module of the
i€ouencer rs connected
\ 'te Malc \ure oflhe shon-(ircuir bar or wire
between the terminals PLC and P24.
J300 scries
@ This is an example when rhe source type
transistor output (open collector output)
module ofthe sequencer is connected
Nole: Male sure of rhe shon-crrcuir b,f or $ i,<
between the terminals CM1 and PLC.
YTS48 type output module
(by Hitachi)
: when the extemal interface powcr source is used
I Thi. i\ an ernmple $hen rhe sink (jpe rran\rsror
output (open collector oulput module ofthe
sequencer rs connect€d
Notc: Remove the short'circuit bar or wire between
the tenninals CMI and PLC or P24 and PLC.
@ This is an example when the source type
transistor output (open collector output)
module ofthe sequencer is connected
Noie: Remove the short-circuit bar or wirc between
the terminals CM I and PLC or P24 and PLC.
J300
YTR48 type ourput module
(by Hitachi)
YTS48 type output module
(by Hitachi)
Nolc: Bc surc 1o turn the inverter on afler thc conrroller and external power sourcc
(Otherwise, the dala in ihe inv€rter may be changed.)
: TR.lli lype outpul module
- \ H i l J e h i )