Technical Characteristics - Bosch W11P Installation And Operating Instructions Manual

Gas instantaneous water heater
Table of Contents

Advertisement

1.6

Technical characteristics

Rated max. heat output
Rated min. heat output
Output (modulation range)
Rated max. heat input
LPG (butane/propane)
LPG (butane/propane)
Temperature control at maximum setting
Temperature increase
Min. operating pressure
Temperature control at minimum setting
Temperature increase
*
H
15°C - 1013 mbar - dry :
i
**
This figure must not be exceeded taking account of water expansion
***
At maximum rated heat output
4
Technical Data
Rated min. heat input
Supply pressure:
Natural gas
Consumption:
Natural gas
Number of injectors
Max. water pressure**
Flow rate
Flow rate
Draught requirement
Flow rate
Temperature
Natural gas
34.2 MJ/m
LPG: Butane 45.7 MJ/kg (12.7 kWh/kg)
Symbol
Unit
P
Btu/h
n
P
Btu/h
min
Btu/h
Q
Btu/h
n
Q
Btu/h
min
mbar (kPa)
mbar (kPa)
3
m
/h
kg/h
p
psi
w
° C
l/min
p
psi
wmin
° C
l/min
mbar
g/s
° C
(9.5 kWh/m
)
3
3
W11
W14
65570
80595
31420
40300
31420 - 65570
40300 - 80595
74450
92210
36200
46105
20 (2.0)
20 (2.0)
28 (2.8)
28 (2.8)
2.2
2.77
1.75
2.2
12
14
170
170
50.0
50.0
5.5
7
2.0
2.0
25
25
11
14
0.015
0.015
13
17
160
170
Propane 46.4 MJ/kg (12.9 kWh/kg)
W18
104165
52082
52082 - 104165
117825
58912
20 (2.0)
28 (2.8)
3.5
2.79
18
170
50.0
8.8
3.0
25
17.6
0.015
22
180
6 720 607 526