AMETEK CTS
3.
Standards for testing with coupling networks of CDN 118A series
The coupling network CDN118A series are suitable for tests according the following standards:
- IEC 61000-4-5
- Surge 1.2/50s as per figure 10 for unshielded symmetrical interconnection lines
- EN 61000-4-5
- IEC 61000-4-5
- Telecom surge 10/700s, Figure A4 for unshielded outdoor symmetrical communica-
- EN 61000-4-5
- ITU-T K.44
Impulse 1.2 s / 50 s
IEC 61000-4-5 Ed.3 Figure 10
Example for n= 4:
Rc = n x 40 Ω = 160 Ω
Operating manual
tion lines
Impulse 10 s / 700 s
IEC 61000-4-5 Ed.3 Figure A4
Example for n= 2:
Rc = 25 Ω
V 1.00
CDN 118A series
7 / 26