Siemens SINAMICS S120 Getting Started page 32

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Configuring the drive object
6.1 Configuring the drive unit
2. Activate the desired target device and click on "OK."
Note
Online/offline comparison
If you create additional projects in the same way in quick succession, the "Online/offline
comparison" dialog appears after closing the target device selection. This dialog indicates
that the data saved in your drive object (of the training case) does not correspond with
the data of the new project. The reason for this is generally because you have configured
settings in the expert list in the last project that are still saved in the target device (the
training case), but which are missing in the newly created project in STARTER (see
section Special issues with the SINAMICS S120 training case (Page 34) and section
Commissioning a drive (Page 37)).
However, as the online and offline configuration has to be identical, the data records have
to be aligned.
1. To do this, click on the "Load to PG ==>" button and confirm the subsequent "Load to
2. If no more differences remain, click on "Close."
3. In the project navigator, click on the "+" symbol before the entry "S120_CU320_2_DP".
30
The target device selection is closed and online mode is active.
PG" prompt with "OK."
The "Online/offline comparison" dialog is emptied.
In general, the settings required for the training case are then already available in the
expert list (see section Special issues with the SINAMICS S120 training case
(Page 34) and section Commissioning a drive (Page 37)).
The list of objects for this drive opens and looks like this:
Figure 6-2
Launch automatic configuration
Getting Started, 01/2013, 6SL3097-4AG00-0BP2
Getting Started

Advertisement

Table of Contents
loading

Table of Contents