Reply_Revision - Symbol SE 923 Integration Manual

Scan engine
Table of Contents

Advertisement

SE-923 Scan Engine Integration Guide

REPLY_REVISION

Description: Reply to REQUEST_REVISION command with software
revision string
Packet Format
Length
Field Descriptions
Field Name
Length
Opcode
Message
Source
Status
Revision
Checksum
Host Requirements
None.
Decoder Requirements
The decoder sends its revision string to the host. The revision string is in the following format:
S/W_REVISION <space> BOARD_TYPE <space> SCANNER_ID <space> PGM_CHKSUM
Where:
S/W_REVISION is the release name of the software
6-26
Opcode
Message Source
0xA4
0x00
Format
Length of message (not
including checksum).
0xA4
0 = Decoder
Bit 0: Retransmit
Bit 1-7: Unused
ASCII data
2's complement sum of
message contents
excluding checksum.
Status
Revision
Size
1 Byte
Length Field
1 Byte
Identifies this Opcode type.
1 Byte
Identifies where the message is
coming from.
1 Byte
Identifies the transmission status.
Unused bits must be set to 0.
variable
Software revision in ASCII (see
format below).
2 Bytes
Checksum of message.
Checksum
Description

Advertisement

Table of Contents
loading