Operating manual EMGZ308 1 Safety Instructions 1.1 Description conditions a) High danger of health injury or loss of life Danger This symbol refers to high risk for persons to get health injury or loss life. It has to be followed strictly.
Strain gauge: Electronic component that will change its resistance while its length has changed. Strain gauges are used in the FMS force sensors for acquisition of the feedback value. 3 System components The EMGZ308 consists of the following components (refer also to fig. 1): Force sensors •...
Due to the wheatstone wiring of the strain gauges, the measured value is according also to the power supply. So, the force sensors are supplied from the EMGZ308 by a very accurate power supply.
Operating manual EMGZ308 Fixed setting of gain and offset Fixed setting is used when maximum thermal stability and vibration-proof conditions are needed. The signal is pre-amplified with a fixed value and has to be evaluated digitally (for ex. by a PLC), so that offset and gain can be calculated.
Operating manual EMGZ308 6 Installation and wiring Caution Proper function of the Tension Measuring Amplifier is only guaranteed with the recommended application of the components. In case of other arrangement, heavy malfunction can be the result. Therefore, the installation instructions on the following pages must be followed strictly.
Operating manual EMGZ308 6.2 Mounting the force sensors Mounting of the force sensors is done referring to the FMS Installation manual which is delivered together with the force sensors. Wiring to the terminals of the electronic unit is done according to wiring diagram (fig. 5).
Operating manual EMGZ308 7 Setting into operation 7.1 View of the setting elements fig. 6: Setting elements E308008e 7.2 Configuring gain and offset Gain and offset are configured by jumpers. The settings can be made individually for each channel. Gain and offset with infinite setting...
4...20mA) which are active simultaneously. The signal of the current output is configured as follows: Current output 0...20mA The jumpers have to be set according to fig. 9. This is the standard FMS factory setting. fig. 9: Jumper setting for current output 0...20mA E308010c Current output 4...20mA...
Operating manual EMGZ308 7.4 Configuring the lowpass filter The measuring amplifier provides 2 lowpass filters per channel. They are used to eliminate faulty signal variations which may be caused by unbalanced rollers, vibrations of the machine, or equivalent. Lowpass U...
Operating manual EMGZ308 7.5 Calibrating the measuring amplifier Proceed the calibration for each channel as follows: • Connect gauge to the tension or current output. • Connect the first force sensor. • Check if a positive output signal is appearing when loading the sensor in measuring direction.
Operating manual EMGZ308 8 Trouble shooting Error Cause Corrective action Offset setting is bad Re-adjust offset (refer to „7.5 Calibrating the Output shows signal > 0 although material has no measuring amplifier“) tension Current output is configured Change jumper setting if required for 4...20mA...
Operating manual EMGZ308 9 Technical Data Sensor excitation 5VDC ±20ppm/K max. 30mA [±11ppm/°F] Gain factor range fixed: 1111; variable: 500...5000 Offset range fixed: 0mV; variable: ±9mV Temperature drift offset fixed: < 20ppm/K [11ppm/°F]; variable: ca. 50ppm/K [28ppm/°F] Linearity error < 0.1% Tension output ±10V min.