11.0 MAINTENANCE & SERVICE
1. Check the tank straps to make sure they stay tight so the tank does not
rotate in the bracket.
2. The system should be fl ushed with clean water if the foam marker is
not going to be used for a period of time.
3. If a polyethylene line has become cut or pinched, line menders
(#23212303 8mm and #23214603 10mm) can be used to make re-
pairs.
4. Make sure that all electrical connections stay clean and free of corro-
sion.
5. Before storing unit for the winter, run a mixture of ethylene glycol
based antifreeze and water through the marker system to keep
components from freezing. The system will have to be fl ushed thor-
oughly with clean water to restore maximum performance to the Foam
Marker.
6. Clean the tank fi lter every 50 hours of operation.
(See instructions and diagram below Fig. 29)
A. Remove the U-clip from the bottom tank fi tting and pull the foam line
fi tting out.
B. Using a needle nose pliers, reach into the tank fi tting, grabbing a
hold of the fi lter and remove by pulling it down.
C. Clean the fi lter with
clean water.
D. Flush the tank using
clean water and let it
drain through the tank
fi tting to remove any re-
main ing foreign material.
E. Replace the fi lter using
the needle nose pliers and
reassemble.
®