Remove the flywheel with the flywheel puller.
Special service tools:
Flywheel puller
Shaft protector
Caution
Install a shaft protector on the right end of
crankshaft to avoid damaging the
crankshaft before installing the flywheel
puller.
Remove the connectors of the A.C.
generator and pulse generator.
Remove the 6 bolts for the pulse generator,
the A.C. generator coil and cable guide.
Then, remove the A.C. generator assembly.
Caution
Do not damage the alternator coil.
RIGHT CRANKCASE COVER
REMOVAL
Remove the right crankcase cover. (8 bolts)
Remove setting pin and gasket.
Remove the gasket or foreign materials on
the connection surfaces of both the cover
and crankcase.
Caution
Do not damage the connection surfaces.
10. A.C. GENERATOR
Flywheel puller
Pulse generator connector
Pulse generator
Coil
8 bolts
generator connector
Cable guide